Dell Storage Center with Solaris 11 Best Practices
Dell Storage Center with Solaris 11 Best Practices
Dell Storage Center with Solaris 11 Best Practices
EMC DSSD D5 Rack-Scale Flash EMC DSSD D5 Rack Scale Flash Appliance for ultra high-performing storage requirements EMC DSSD D5 thumbnail view EMC DSSD D5 Rack-Scale Flash EMC DSSD D5 Rack-Scale Flash EMC DSSD D5 Rack-Scale Flash Give high-performance applications and real-time analytics what they need with EMC DSSD D5. DSSD D5 introduces rack-scale flash,… Read More: EMC DSSD D5 Rack-Scale Flash »
Creating Default Services The following virtual device services must be created to use the control domain as a service domain and to create virtual devices for other domains: vcc – Virtual console concentrator service vds – Virtual disk server vsw – Virtual switch service How to Create Default Services Create a virtual console concentrator (vcc)… Read More: Oracle VM server 3.4 »
The general way to send ZFS data sets to remote nodes is normally achieved by sending the ZFS stream through ssh. Example: zfs send zones/UUID@snapshot | ssh [email protected] zfs recv zones/UUID The down side with this method is that ssh encryption is slow and has significant cpu overhead. You may find yourself in situations where… Read More: Fast ZFS Send with Netcat »
https://blogs.oracle.com/openomics/entry/solaris_zone_migration comandos útiles de zfs para snapshots: https://docs.oracle.com/cd/E18752_01/html/819-5461/gbchx.html By Amir Javanshir-Oracle on Jun 18, 2013 As part of my job in the ISV Engineering team, I am often asked by partners the following question : is it possible to easily move a Solaris 11 Zone from a physical server to another? The short answer is… Read More: Moving Oracle Solaris 11 Zones between physical servers »
You can configure NPIV for non-virtualized environments by using the fcadm command. The fcinfo and fcadm status commands are available to determine the status of NPIV ports, whether the ports are created from fcadm. The commands also report the relationship between the physical port and the virtual ports hosted on that port. Other Fibre Channel… Read More: Creating NPIV Ports »
http://thegeekdiary.com/ldoms-ovm-for-sparc-command-line-reference-cheat-sheet/
You do not have write access VNTSD commands ~w –Force write access Warning: another user currently has write permission to this console and forcibly removing him/her will terminate any current write action and all work will be lost. Would you like to continue?[y/n] y
IPMP and link aggregation are different technologies to achieve improved network performance as well as maintain network availability. In general, you deploy link aggregation to obtain better network performance, while you use IPMP to ensure high availability. The following table presents a general comparison between link aggregation and IPMP. IPMP Link Aggregation Network technology… Read More: Comparing IPMP and Link Aggregation »
Save your domain configuration: after making a change to your domains configuration that you want to persist overapowercycle,saveittotheserviceprocessorbyissuinganldm add-config confignamecommand. ‘bootsets’ containing the Service Processor (SP configuration and constraints are saved on the control domain when a configuration is saved to the SP, and are used to reload the constraints database after a power cycle.… Read More: Ldm save export »